Fault Phenomena, Possible Causes and Troubleshooting Methods for Excessive Pressure in Air Compressor Air Storage Tank
Jan 21 , 2026

1. Insufficient cooling water flow in the cooler (water-cooled models only): Clean the cooler. Inspect the water system for faults, including the water temperature control valve; readjust or clean the valve if necessary.

2. Inadequate air circulation in the cooler: Check the cooler’s installation position to ensure there is no obstruction to air flow. Inspect the cooler and clean it if needed.

3. Low oil level in the oil-gas separator: Refill the oil to the recommended level and check the oil circuit system for leaks.

4. Clogged oil filter: Replace the oil filter element.

5. Clogged oil cooler: Check for the presence of varnish and rust scale. Thoroughly clean the cooler in accordance with the methods recommended by the heat exchanger manufacturer.

6. Excessively high ambient temperature: Ensure the ambient temperature does not exceed the maximum allowable operating temperature of the unit.

7. Incorrect fan rotation direction: The correct direction is for the fan to blow air into the cooler. Swap any two phases of the three-phase power supply lines.

8. Inappropriate lubricating oil: Use Baolite rotor lubricating oil. Refer to the lubrication section for details.

9. Clogged air filter: Clean or replace the air filter.

10. Damaged temperature control valve: Repair or replace it as required.

11. Damaged compressor head: Contact Baolite After-sales Service Department.

 