YILUMA SE-30 is a 22 kW single-stage PM VSD screw air compressor with an IE4 permanent magnet motor and direct drive. Air delivery is 3.2 m³/min at 0.8 MPa and 2.8 m³/min at 1.0 MPa. The air-cooled cabinet measures 830 × 750 × 1250 mm, weighs 200 kg and has a G3/4 outlet.
Item NO.:
SE-30Product Origin:
Quanzhou, Fujian, ChinaColor:
Dark gray cabinet with black baseProduct weight:
200 kgShipping Port:
XiamenLead Time:
Depends on configurationThe YILUMA SE-30 is a 22 kW cabinet unit for a dedicated production area. It supplies compressed air for production cells, assembly workshops and grouped pneumatic equipment. Its oil-injected single-stage airend is paired with an IE4 permanent magnet motor and integrated direct drive. Variable-frequency control adjusts operation as air demand changes.
The 22 kW package delivers 3.2 m³/min at 0.8 MPa and 2.8 m³/min at 1.0 MPa. Dimensions are 830 × 750 × 1250 mm, unit weight is 200 kg and the air outlet is G3/4. The selected configuration uses a 380–415 V, three-phase, 50 Hz supply. Specify receiver and air treatment separately for the intended system.
1. 22 kW single-stage output for the selected duty
The SE-30 delivers 3.2 m³/min at 0.8 MPa or 2.8 m³/min at 1.0 MPa. Review tool or process consumption at the required pressure when selecting a compressor for production cells, assembly workshops and grouped pneumatic equipment.
2. IE4 permanent magnet motor with integrated direct drive
The compressor uses an IE4 permanent magnet motor with IP23 motor protection and a direct-drive arrangement. The listed motor-speed value is 4000 rpm. IP23 describes the motor; review the installation environment when planning the package position.
3. Variable-frequency starting and demand response
The PM VSD system adjusts motor operation as air demand changes and uses variable-frequency starting. Set the operating pressure to the process requirement and review the actual duty profile when assessing energy use.
4. Axial cooling fan and planned airflow
A top-mounted axial fan and lower air inlets form the cooling-air path. Keep intake and exhaust routes clear and provide ventilation that removes heat from the installation area.
5. Intake filtration and oil separation
An intake filter and a separator using centrifugal, gravity and filtration stages support the oil-injected compression system. Select any downstream air treatment according to the required process air quality.
6. Accessible oil-service arrangement
The oil-drain arrangement provides access for routine lubricant service. The lubricating oil quantity is 7 L. Use the specified lubricant and replacement components and keep service points accessible after installation.
7. Defined cabinet size and outlet connection
The SE-30 measures 830 × 750 × 1250 mm and weighs 200 kg, with a G3/4 air outlet. Review the complete access route, operating space and distribution connection before finalizing the equipment layout.
YILUMA SE-30 · 22 kW · Single-stage PM VSD screw compressor
| Parameter | SE-30 |
|---|---|
| Model | SE-30 |
| Compressor type | Oil-injected single-stage PM VSD screw compressor |
| Motor power | 22 kW |
| Motor efficiency class | IE4 permanent magnet motor |
| Motor protection | IP23 (motor) |
| Air delivery at 0.8 MPa | 3.2 m³/min |
| Air delivery at 1.0 MPa | 2.8 m³/min |
| Drive arrangement | Direct drive |
| Starting method | Variable-frequency starting |
| Motor speed | 4000 rpm |
| Cooling method | Air cooling |
| Discharge temperature | ≤ Ambient temperature + 15°C |
| Power supply | 380–415 V / 3-phase / 50 Hz |
| Lubricating oil quantity | 7 L |
| Noise level | 75 ± 2 dB(A) |
| Dimensions (L × W × H) | 830 × 750 × 1250 mm |
| Unit weight | 200 kg |
| Air outlet | G3/4 |
| Product origin | Quanzhou, Fujian, China |
Values shown describe the selected 380–415 V, three-phase, 50 Hz configuration. Delivery values apply to the stated pressure points. The motor-speed entry is the listed model value, not a guaranteed full variable-speed operating range. IE4 and IP23 refer to the motor. Confirm any alternative supply configuration separately.
Pressure and demand: Use 3.2 m³/min at 0.8 MPa or 2.8 m³/min at 1.0 MPa when checking simultaneous demand. Allow for distribution losses and the intended operating hours.
Electrical configuration: The selected supply is 380–415 V, three-phase, 50 Hz. Provide the actual site voltage and frequency so that the compressor and control configuration can be confirmed.
Space and ventilation: Plan for 830 × 750 × 1250 mm dimensions and 200 kg weight. Maintain lower-inlet and top-exhaust clearance, service access and a suitable environment for the IP23 motor.
Receiver and air treatment: Select the receiver, dryer and downstream filters for the required air quality and duty. The cabinet compressor connects through a G3/4 outlet; treatment scope is defined separately in the quotation.
| Before you order | What to confirm |
|---|---|
|
Quotation requirements |
Please provide your required operating pressure, average and peak air demand, power supply, order quantity and destination. |
|
Equipment scope |
The quotation specifies the selected compressor configuration and any receiver, dryer, filters or accessories included. |
|
Delivery and shipment |
Production lead time and shipping arrangements are quoted according to the selected configuration, quantity and destination. |
|
Technical documentation |
Please identify any documentation or destination-specific requirements needed for your purchasing process so that we can assess them for the selected configuration. |
|
Warranty and after-sales support |
Warranty coverage, service arrangements and spare-parts support are defined in the agreed quotation and order documents. |
Explore HUADA’s manufacturing facilities and request the technical documentation relevant to your selected configuration and destination.
View our factory
Review qualification documents
What should be checked when installing the SE-30?
Allow for its 830 × 750 × 1250 mm dimensions, 200 kg weight and G3/4 air outlet, as well as service access and an unobstructed cooling-air path. Check the required flow at the chosen pressure: 3.2 m³/min at 0.8 MPa or 2.8 m³/min at 1.0 MPa.
Does this cabinet unit include a receiver and refrigerated dryer?
The specifications on this page describe the standalone compressor cabinet. Specify a receiver, dryer, filters and drains separately according to the air network and process requirements. The quotation identifies the equipment included in the selected supply.
Do IE4 and IP23 describe the complete compressor package?
IE4 is the motor efficiency class and IP23 is the motor protection rating. They do not define the protection or efficiency of every component in the compressor package. Review the installation environment, cooling ventilation and electrical arrangement for the complete system.
How should I assess variable-speed operation for this model?
Compare the actual demand profile with 3.2 m³/min at 0.8 MPa or 2.8 m³/min at 1.0 MPa, and confirm the required control settings. The listed motor-speed entry is 4000 rpm; it should not be treated as the complete allowable variable-speed control range.
07 Request a Quotation for SE-30
Contact us to specify the YILUMA SE-30 for your air system. Send the required operating pressure, average and peak air consumption, site power supply and operating hours so that we can review the selected 22 kW configuration.
Include the required outlet air quality, installation conditions, order quantity and destination. We will confirm the equipment scope, technical configuration, delivery arrangements and quotation for your application.
Leave A Message