For a 75 kW screw air compressor, the answer changes with the pressure configuration. HUADA lists 16.5 m³/min for the LGGPM-100+ in its 0.6–0.8 MPa configuration, above a 14 m³/min requirement. In the 0.6–1.0 MPa configuration, its listed delivery is 12.5 m³/min. The 90 kW LGGPM-125+ then becomes the next model to consider.
Consider an illustrative production line requiring 14 m³/min at the compressor outlet. Assume this demand and the catalogue air deliveries use the same flow reference conditions. Compare two pressure configurations, keeping airflow demand unchanged. Establish the required outlet pressure from the equipment pressure plus losses through the dryer, filters and pipework.

The 75 kW model has a listed surplus of 2.5 m³/min in the lower-pressure configuration, but a 1.5 m³/min shortfall in the higher-pressure configuration. The LGGPM-125+ lists 16.9 m³/min in the latter, making it the next larger catalogue model to check for this demand. Confirm delivery at the intended operating point and the allowance needed before ordering.
Higher discharge pressure requires more compression work for each equivalent volume of intake air. A higher-pressure configuration can therefore deliver less airflow within the same motor power size. A two-stage screw air compressor divides compression between two stages, while variable-speed control adjusts output to changing demand. Neither feature removes the capacity limit. An air receiver can buffer brief peaks; it cannot sustain a continuous 1.5 m³/min supply shortfall.

Moving to the 90 kW screw air compressor also changes the installation requirements. Both the LGGPM-100+ and LGGPM-125+ measure 2540 × 1616 × 2350 mm and use a DN65 outlet. However, the listed weight rises from 2622 to 3015 kg, and motor power rises from 75 to 90 kW. Check electrical capacity, floor loading and handling access, then review dryer and filter capacity for the selected duty.
For a selection check, send HUADA your required pressure at the equipment, peak and normal airflow demand, how long peak demand lasts, and available power supply. Include the existing dryer and filter details. We can review the pressure configuration and model against your line’s operating conditions. Request a selection check.