Item NO.:
TPK-B50AProduct Origin:
Quanzhou, Fujian, ChinaColor:
Orange and dark grayProduct weight:
95 kgShipping Port:
To be confirmed in quotationLead Time:
Depends on configurationThe HUADA TPK-B50A provides a variable-frequency refrigerated drying stage for a 6.5 m³/min nominal duty. Designed for shared workshop air networks and production equipment with changing demand, it removes moisture from compressed air by cooling the air, separating condensed water and discharging the condensate automatically.
This variable-frequency model has a nominal air treatment capacity of 6.5 m³/min and uses R410A refrigerant. The pressure-dew-point range is 2–10°C, subject to operating conditions. The package measures 680 × 620 × 900 mm, weighs 95 kg and connects through G1 1/2 air ports.
1. 6.5 m³/min nominal air-treatment capacity
The TPK-B50A is sized for a nominal treatment capacity of 6.5 m³/min. Match the dryer to the actual compressed-air flow, working pressure, inlet temperature and ambient conditions when planning shared workshop air networks and production equipment with changing demand.
2. Variable-frequency operation with a 0.39–1.4 kW listed range
The TPK-B50A belongs to the variable-frequency TPK series and has a listed total unit power range of 0.39–1.4 kW. Review the operating load and inlet conditions when assessing dryer power use and selecting the electrical supply.
3. Air-to-air heat recovery and outlet reheat
Incoming warm compressed air exchanges heat with the outgoing cold, dry air before entering the evaporator. This precools the inlet air and recovers cooling energy. The outgoing dry air is reheated before leaving the dryer.
4. Refrigerated moisture condensation and separation
The refrigeration stage cools compressed air so that water vapor condenses. The separator removes the resulting liquid from the air stream. The 2–10°C pressure-dew-point range is dependent on operating conditions and should be checked against the process requirement.
5. Automatic condensate drainage
Separated water is discharged through an automatic drain, reducing the need for manual emptying. Keep the drain accessible and provide a suitable condensate discharge route so that collected water can leave the dryer.
6. Microcomputer control and integrated system layout
Temperature sensors work with the microcomputer control system to monitor operation and support protective functions. The heat-exchange, refrigeration and electrical-control sections are integrated in one cabinet for an orderly installation and routine servicing.
7. Defined connection and cabinet size
The TPK-B50A uses G1 1/2 air connections, measures 680 × 620 × 900 mm and weighs 95 kg. These values support pipework, handling and service-access planning. The supplied product appearance combines orange panels with a dark gray cabinet.
HUADA TPK-B50A · 6.5 m³/min nominal treatment capacity · Variable-frequency refrigerated air dryer
| Parameter | TPK-B50A |
|---|---|
| Performance and control | |
| Model | TPK-B50A |
| Dryer type | Refrigerated compressed air dryer |
| Control type | Variable-frequency |
| Nominal air treatment capacity | 6.5 m³/min |
| Pressure dew point | 2–10°C (subject to operating conditions) |
| Power supply and refrigeration | |
| Power supply | 220 V / 50 Hz |
| Total unit power range | 0.39–1.4 kW |
| Refrigerant | R410A |
| Connections and dimensions | |
| Air inlet/outlet connection | G1 1/2 |
| Overall dimensions | 680 × 620 × 900 mm |
| Unit weight | 95 kg |
| Product origin | Quanzhou, Fujian, China |
Air treatment capacity is a nominal model value. Select the dryer for the actual inlet temperature, ambient temperature, working pressure, air flow and required pressure dew point. The stated 2–10°C range is subject to operating conditions. Dimensions follow the listed sequence; confirm connection and installation details in the quotation.
Air flow and drying duty: Check the actual flow against the 6.5 m³/min nominal capacity. State the working pressure, inlet and ambient temperatures, and required pressure dew point so that the dryer can be selected for the intended duty.
Electrical supply: The specified supply is 220 V / 50 Hz. The listed total unit power range is 0.39–1.4 kW. Confirm phase, protection and connection details for the installation.
Pipework and condensate: Plan the connection to the G1 1/2 inlet/outlet ports, allow access to the condensate drain and provide a suitable discharge route. Specify any upstream or downstream filtration required for the process.
Position and maintenance: Allow for the 680 × 620 × 900 mm overall dimensions and 95 kg unit weight. Keep cabinet ventilation openings clear and provide access to controls, drain components and service panels.
| Before you order | What to confirm |
|---|---|
|
Quotation requirements |
Please provide your required operating pressure, average and peak air demand, power supply, order quantity and destination. |
|
Equipment scope |
The quotation specifies the selected equipment configuration and any receiver, dryer, filters or accessories included. |
|
Delivery and shipment |
Production lead time and shipping arrangements are quoted according to the selected configuration, quantity and destination. |
|
Technical documentation |
Please identify any documentation or destination-specific requirements needed for your purchasing process so that we can assess them for the selected configuration. |
|
Warranty and after-sales support |
Warranty coverage, service arrangements and spare-parts support are defined in the agreed quotation and order documents. |
Explore HUADA’s manufacturing facilities and request the technical documentation relevant to your selected configuration and destination.
View our factory
Review qualification documents
What does the TPK-B50A power range mean?
The TPK-B50A has a listed total unit power range of 0.39–1.4 kW. It is a variable-frequency refrigerated dryer with a nominal treatment capacity of 6.5 m³/min. The range describes the dryer’s listed power specification; it is not a fixed consumption value for every operating condition or the power rating of the upstream air compressor.
Can I select this dryer using compressor motor power alone?
Use the actual compressed-air flow and operating conditions. The TPK-B50A has a nominal treatment capacity of 6.5 m³/min, while the required selection also depends on working pressure, inlet temperature, ambient temperature and the target pressure dew point. Compressor motor power alone does not define the dryer duty.
Does a 2–10°C pressure dew point describe the outlet air temperature?
Pressure dew point describes the moisture condition of compressed air at operating pressure. It is different from the outlet air temperature. In this dryer, the outgoing dry air passes back through the air-to-air heat exchanger and is reheated before discharge. Verify the required dew point for the actual operating conditions.
Does refrigerated drying also define the complete air-purity grade?
This dryer removes moisture by refrigeration, liquid separation and automatic drainage. Select additional filtration and any further treatment according to the process requirements. A specified dew point by itself does not establish the complete particle, oil or application-specific air-purity requirement.
07 Request a Quotation for TPK-B50A
Request a quotation for the HUADA TPK-B50A. Send the actual compressed-air flow, working pressure, inlet temperature, ambient temperature and required pressure dew point so that we can review the selected 6.5 m³/min nominal dryer configuration.
Include the site power supply, connection requirements, required filtration, operating hours, order quantity and destination. We will confirm the equipment configuration, installation information and commercial terms for your air-treatment system.
Leave A Message