The HUADA TVD-60+ is a 45 kW two-stage permanent magnet VSD screw air compressor for industrial networks with higher air demand. At 0.7 MPa, its listed delivery is 9.7 m³/min for the 0.6-0.8 MPa version or 7.8 m³/min for the 0.6-1.0 MPa version. The package uses air cooling and a G2 outlet.
Item NO.:
TVD-60+Product Origin:
Quanzhou, Fujian, ChinaColor:
Orange and dark grayProduct weight:
1560 kgShipping Port:
XiamenLead Time:
Depends on configuration
Consider the TVD-60+ when the measured demand of a shared factory network exceeds the TVD-50+ capacity. It offers a 45 kW capacity step before the 55 kW TVD-75+, allowing selection around the air delivery actually required by the plant.
The TVD-60+ shares the TVD-75+ listed dimensions and weight: 2000 × 1546 × 1785 mm and 1560 kg. Plan handling, room ventilation and electrical demand accordingly, and confirm the separator arrangement and service access for the ordered configuration.
1. 9.7 m³/min for a higher-demand factory network
The 0.6-0.8 MPa version is listed at 9.7 m³/min at 0.7 MPa. This provides more air than the corresponding TVD-50+ version for systems whose measured demand justifies the additional capacity.
2. 7.8 m³/min for the wider pressure-range version
For the 0.6-1.0 MPa working range, listed delivery at 0.7 MPa is 7.8 m³/min. Evaluate this version using its own duty-point data when specifying the plant air system.
3. 45 kW permanent magnet variable-speed operation
The permanent magnet drive adjusts compressor speed as network demand changes. The 45 kW motor provides a distinct power and capacity option between the 37 kW and 55 kW models.
4. Two-stage transmission without interstage gears
The horizontal integrated drive follows the TVD+ design that avoids interstage gears, eliminating those gears as a source of transmission loss and noise within the compression drive.
5. A defined large-cabinet installation envelope
Dimensions of 2000 × 1546 × 1785 mm and a listed weight of 1560 kg give project teams concrete figures for access and placement. The same listed envelope is used by the TVD-75+.
6. Axial-fan cooling with a stated acoustic rating
The air-cooled design uses an axial fan, and the listed noise level is 75 ± 2 dB(A). Review cooling-air circulation and equivalent noise test conditions when evaluating the equipment-room installation.
7. Operating visibility for a shared air system
A dedicated controller and motor protection functions support routine checks of the 45 kW package. Remote monitoring requirements can be assessed for the selected configuration and installation country.
HUADA TVD-60+ 45 kW two-stage screw air compressor.
| Parameter | TVD-60+ |
|---|---|
| Model | TVD-60+ |
| Motor power | 45 kW |
| Listed discharge pressure | 0.7 MPa |
| 0.6-0.8 MPa working range |
Air delivery at 0.7 MPa: 9.7 m³/min Listed motor speed: 2500 rpm |
| 0.6-1.0 MPa working range |
Air delivery at 0.7 MPa: 7.8 m³/min Listed motor speed: 2100 rpm |
| Power supply | 380-400 V / 50 Hz |
| Starting method | Variable-frequency starting |
| Cooling method | Air cooling with axial fan |
| Drive layout | Horizontal two-stage integrated transmission |
| Lubricant quantity | 54 L |
| Listed noise level | 75 ± 2 dB(A) |
| Dimensions (L × W × H) | 2000 × 1546 × 1785 mm |
| Weight | 1560 kg |
| Air outlet connection | G2 |
| Oil separator | Confirm separator configuration for the ordered unit |
The air-delivery and motor-speed figures refer to two different pressure-range versions, both listed at 0.7 MPa; they are not the minimum and maximum of a VSD adjustment range. Request performance at the required operating pressure and confirm the electrical specification before ordering. Compare noise levels only under equivalent test conditions.
Industrial demand: Provide network-wide average and peak demand, shift patterns and planned expansion. Compare the required duty point with 9.7 or 7.8 m³/min at 0.7 MPa for the selected version.
Electrical and ventilation planning: Review the 45 kW power requirement, handling route for 1560 kg and cooling-air circulation around the 2000 × 1546 × 1785 mm cabinet.
System integration: Check G2 pipework, receiver and treatment capacity. The listed lubricant quantity is 54 L; confirm the separator arrangement and the required maintenance access before finalizing the layout.
Air quality: Specify the required moisture, particle and oil levels for the plant applications. The TVD-60+ is lubricated; downstream treatment should be selected for the required air quality.
| Before you order | What to confirm |
|---|---|
|
Quotation requirements |
Please provide your required operating pressure, average and peak air demand, power supply, order quantity and destination. |
|
Equipment scope |
The quotation specifies the selected compressor configuration and any receiver, dryer, filters or accessories included. |
|
Delivery and shipment |
Production lead time and shipping arrangements are quoted according to the selected configuration, quantity and destination. |
|
Technical documentation |
Please identify any documentation or destination-specific requirements needed for your purchasing process so that we can assess them for the selected configuration. |
|
Warranty and after-sales support |
Warranty coverage, service arrangements and spare-parts support are defined in the agreed quotation and order documents. |
Explore HUADA’s manufacturing facilities and request the technical documentation relevant to your selected configuration and destination.
View our factory
Review qualification documents
How does the TVD-60+ differ from the TVD-75+?
The TVD-60+ has a 45 kW motor and the TVD-75+ has a 55 kW motor. Their corresponding listed outputs at 0.7 MPa are 9.7 versus 12.1 m³/min, or 7.8 versus 9.6 m³/min. Listed dimensions and weight are the same.
Is 9.7 m³/min available across the full pressure range?
No. It is the listed output at 0.7 MPa for the 0.6-0.8 MPa version. The 0.6-1.0 MPa version is listed at 7.8 m³/min at 0.7 MPa. Request data for the required operating pressure.
Which oil-separator arrangement will be supplied?
Please confirm the separator configuration in the quotation and technical specification for the ordered TVD-60+. Service clearance and the separator-element replacement procedure should be checked against that configuration.
Can remote monitoring be included for a factory air station?
Send your monitoring requirements and installation country. The gateway, network connection, available functions and service coverage need to be confirmed for the selected TVD-60+ configuration.
07 Request a TVD-60+ Quotation
Send your factory network’s required pressure, average and peak air demand, operating shifts, power supply, quantity and destination. We will review whether the 45 kW TVD-60+ provides the appropriate capacity and prepare a quotation.
Include room dimensions, the equipment access route, G2 pipework and air-treatment requirements. Separator configuration and any remote monitoring requirements can then be confirmed with the project specification.
Leave A Message