Item NO.:
LGGPM-50Product Origin:
Quanzhou, Fujian, ChinaColor:
Orange with dark panelsProduct weight:
1070 kgShipping Port:
XiamenLead Time:
Depends on configurationThe LGGPM-50 is a 37 kW two-stage PM VSD compressor for sites moving from a smaller air supply to a shared production-line system. Air delivery is 7.1 m³/min at 0.8 MPa, with a G1½ outlet and a unit size of 1676 × 1226 × 1610 mm.
The machine combines a relatively compact enclosure with pressure-specific output data. For an upgrade, check existing pipework and treatment capacity alongside the compressor rather than selecting by motor power alone.
1. 37 kW output for shared workshop demand
The LGGPM-50 delivers 7.1 m³/min at 0.8 MPa with a 37 kW motor. Use this output when checking several tools or machines operating at the same time.
2. Compression split across two stages
The first stage raises air to an intermediate pressure before the second stage completes compression. Oil-mist cooling between the stages helps control the temperature rise through the process.
3. PM VSD control for changing tool demand
A permanent magnet motor and variable-frequency drive adjust compressor speed with demand. Direct transmission keeps the motor-to-airend connection free of a belt drive.
4. Variable-speed centrifugal fan cooling
The 37 kW air-cooled package uses variable-speed centrifugal fan cooling. The cooling-air system supports heat removal without a cooling-water circuit; keep the inlet and discharge paths clear.
5. Defined envelope for a workshop upgrade
The unit measures 1676 × 1226 × 1610 mm and weighs 1070 kg. These figures support delivery-route and room-layout checks; allow additional space for service and cooling airflow.
6. G1½ outlet with pressure-specific performance
The G1½ air outlet connects the compressor to the air system. Delivery is 7.2 m³/min at 0.7 MPa and 6.3 m³/min at 1.0 MPa, allowing selection at the pressure the process needs.
7. Accessible oil-separation system
The oil-air separation system uses a vertical separator-vessel arrangement to support maintenance access. The oil filter and separator remain scheduled service items in the lubricated compression system.
HUADA LGGPM-50 37 kW air-cooled two-stage PM VSD screw compressor, shown with an orange enclosure and dark panels.
| Parameter | LGGPM-50 |
|---|---|
| Model | LGGPM-50 |
| Compressor type | Two-stage permanent magnet VSD screw compressor |
| Motor power | 37 kW |
| Air delivery at 0.7 MPa | 7.2 m³/min |
| Air delivery at 0.8 MPa | 7.1 m³/min |
| Air delivery at 1.0 MPa | 6.3 m³/min |
| Air delivery at 1.2 MPa | 5.4 m³/min |
| Drive arrangement | Direct drive |
| Starting method | Variable-frequency starting |
| Motor speed | 3000 rpm |
| Cooling method | Air cooling; variable-speed centrifugal fans |
| Discharge temperature | Ambient temperature ± 15°C |
| Power supply | 380 V / 3-phase / 50 Hz |
| Lubricating oil quantity | 23 L |
| Noise level | 72 ± 3 dB(A) |
| Dimensions (L × W × H) | 1676 × 1226 × 1610 mm |
| Unit weight | 1070 kg |
| Air outlet | G1½ |
Air-delivery values correspond to the individual pressure points shown; they are not a VSD minimum-to-maximum flow range. Confirm the required pressure configuration and site conditions when ordering. Motor speed is a specification reference, not a stated VSD speed range; compare noise levels under equivalent measurement conditions.
Pressure and demand: For a growing workshop or production line with several air users, provide average and peak consumption, working hours and pressure losses to the point of use. Use 7.1 m³/min for the 0.8 MPa duty point.
Electrical and cooling provision: Check the 37 kW motor and 380 V / 3-phase / 50 Hz supply with the installation team. The centrifugal fan system requires an unobstructed cooling-air inlet and a suitable hot-air discharge route.
Handling and connections: Plan for the 1676 × 1226 × 1610 mm cabinet, 1070 kg unit weight and G1½ connection. Obtain the installation drawing and allow the required service and ventilation clearances.
Air quality and site conditions: Specify the receiver, dryer and filters for the required process air quality. Report high temperature, high humidity, severe cold, altitude or heavy dust so that the proposed configuration can be reviewed for the actual site.
| Before you order | What to confirm |
|---|---|
|
Quotation requirements |
Please provide your required operating pressure, average and peak air demand, power supply, order quantity and destination. |
|
Equipment scope |
The quotation specifies the selected compressor configuration and any receiver, dryer, filters or accessories included. |
|
Delivery and shipment |
Production lead time and shipping arrangements are quoted according to the selected configuration, quantity and destination. |
|
Technical documentation |
Please identify any documentation or destination-specific requirements needed for your purchasing process so that we can assess them for the selected configuration. |
|
Warranty and after-sales support |
Warranty coverage, service arrangements and spare-parts support are defined in the agreed quotation and order documents. |
Explore HUADA’s manufacturing facilities and request the technical documentation relevant to your selected configuration and destination.
View our factory
Review qualification documents
What airflow does the LGGPM-50 provide at different pressures?
Air delivery is 7.2 m³/min at 0.7 MPa, 7.1 m³/min at 0.8 MPa, 6.3 m³/min at 1.0 MPa and 5.4 m³/min at 1.2 MPa. Specify the pressure required by the application when selecting the configuration.
What cooling arrangement does this 37 kW model use?
The LGGPM-50 is air-cooled and uses variable-speed centrifugal fans. A process cooling-water circuit is not required for this version; adequate cooling-air supply and hot-air discharge remain essential.
Can this model replace a smaller compressor on existing pipework?
Check the required airflow at the same pressure, connection size, electrical capacity and the ratings of the receiver, dryer and filters. Existing pipework should be assessed for pressure loss at the new flow rate.
Is the motor-speed figure a VSD operating range?
The motor-speed specification is 3000 rpm. It is a single reference figure, not the minimum-to-maximum operating range of the variable-speed drive. Request the operating limits for the selected configuration when needed.
07 Request an LGGPM-50 Quotation
Request an LGGPM-50 quotation with your required pressure, average and peak air demand, operating hours, available power supply, quantity and destination.
For a replacement, include the existing machine specification and the sizes of the connected receiver, dryer and distribution pipework.
Leave A Message