Item NO.:
LGGPM-175Product Origin:
ChinaColor:
Orange with dark panelsProduct weight:
3050 kgShipping Port:
XiamenLead Time:
Depends on configuration
The LGGPM-175 is a 132 kW two-stage PM VSD compressor for plants evaluating a DN80-connected central air supply. Air delivery is 28.0 m³/min at 0.8 MPa, with a DN80 outlet and a unit size of 2430 × 1980 × 2095 mm.
The model combines substantial airflow with a cabinet suited to a planned compressor-room installation. Include peak demand, pressure losses and existing treatment equipment in the sizing exercise so that the compressor is matched to the complete network.
1. 132 kW supply through a DN80 outlet
The LGGPM-175 delivers 28.0 m³/min at 0.8 MPa with a 132 kW motor. This operating point provides a basis for reviewing the combined air demand of several departments.
2. Two-stage compression with intermediate cooling
The pressure rise is shared by two compression stages. Oil-mist cooling between them helps manage heat through the airend as the compressor supplies the selected pressure configuration.
3. Permanent magnet control for mixed production loads
Variable-frequency control adjusts the permanent magnet motor speed as plant consumption changes. Direct transmission keeps the drive connection free of a belt stage.
4. Variable-speed axial fan cooling
The 132 kW air-cooled package uses variable-speed axial fan cooling. The axial fan arrangement supports cooling airflow through the package; plan adequate inlet air and a clear hot-air discharge route.
5. Installation and handling figures for a central station
The unit measures 2430 × 1980 × 2095 mm and weighs 3050 kg. These figures support delivery-route and room-layout checks; allow additional space for service and cooling airflow.
6. DN80 outlet with pressure-specific performance
The DN80 air outlet connects the compressor to the air system. Delivery is 30.0 m³/min at 0.7 MPa and 23.5 m³/min at 1.0 MPa, allowing selection at the pressure the process needs.
7. Remote operating-data visibility
The series IoT system supports remote monitoring, fault warnings and maintenance reminders. Confirm the communication hardware, network access and enabled functions for the supplied configuration.
HUADA LGGPM-175 132 kW air-cooled two-stage PM VSD screw compressor, shown with an orange enclosure and dark panels.
| Parameter | LGGPM-175 |
|---|---|
| Model | LGGPM-175 |
| Compressor type | Two-stage permanent magnet VSD screw compressor |
| Motor power | 132 kW |
| Air delivery at 0.7 MPa | 30.0 m³/min |
| Air delivery at 0.8 MPa | 28.0 m³/min |
| Air delivery at 1.0 MPa | 23.5 m³/min |
| Air delivery at 1.2 MPa | 19.8 m³/min |
| Drive arrangement | Direct drive |
| Starting method | Variable-frequency starting |
| Motor speed | 1500 rpm |
| Cooling method | Air cooling; variable-speed axial fans |
| Discharge temperature | Ambient temperature ± 15°C |
| Power supply | 380 V / 3-phase / 50 Hz |
| Lubricating oil quantity | 90 L |
| Noise level | 82 ± 2 dB(A) |
| Dimensions (L × W × H) | 2430 × 1980 × 2095 mm |
| Unit weight | 3050 kg |
| Air outlet | DN80 |
Air-delivery values correspond to the individual pressure points shown; they are not a VSD minimum-to-maximum flow range. Confirm the required pressure configuration and site conditions when ordering. Motor speed is a specification reference, not a stated VSD speed range; compare noise levels under equivalent measurement conditions.
Pressure and demand: For a central air supply serving several production areas, provide average and peak consumption, working hours and pressure losses to the point of use. Use 28.0 m³/min for the 0.8 MPa duty point.
Electrical and cooling provision: Check the 132 kW motor and 380 V / 3-phase / 50 Hz supply with the installation team. The axial fan system requires an unobstructed cooling-air inlet and a suitable hot-air discharge route.
Handling and connections: Plan for the 2430 × 1980 × 2095 mm cabinet, 3050 kg unit weight and DN80 connection. Obtain the installation drawing and allow the required service and ventilation clearances.
Air quality and site conditions: Specify the receiver, dryer and filters for the required process air quality. Report high temperature, high humidity, severe cold, altitude or heavy dust so that the proposed configuration can be reviewed for the actual site.
| Before you order | What to confirm |
|---|---|
|
Quotation requirements |
Please provide your required operating pressure, average and peak air demand, power supply, order quantity and destination. |
|
Equipment scope |
The quotation specifies the selected compressor configuration and any receiver, dryer, filters or accessories included. |
|
Delivery and shipment |
Production lead time and shipping arrangements are quoted according to the selected configuration, quantity and destination. |
|
Technical documentation |
Please identify any documentation or destination-specific requirements needed for your purchasing process so that we can assess them for the selected configuration. |
|
Warranty and after-sales support |
Warranty coverage, service arrangements and spare-parts support are defined in the agreed quotation and order documents. |
Explore HUADA’s manufacturing facilities and request the technical documentation relevant to your selected configuration and destination.
View our factory
Review qualification documents
What airflow does the LGGPM-175 provide at different pressures?
Air delivery is 30.0 m³/min at 0.7 MPa, 28.0 m³/min at 0.8 MPa, 23.5 m³/min at 1.0 MPa and 19.8 m³/min at 1.2 MPa. Specify the pressure required by the application when selecting the configuration.
What cooling arrangement does this 132 kW model use?
The LGGPM-175 is air-cooled and uses variable-speed axial fans. A process cooling-water circuit is not required for this version; adequate cooling-air supply and hot-air discharge remain essential.
What changes when integrating a DN80 compressor connection?
Review the station manifold, isolation fittings, pipe supports and pressure losses. The receiver, dryer and filters must also be rated for the selected flow and pressure; the outlet designation alone does not establish system capacity.
Can maintenance teams view operating information remotely?
The series supports IoT operating-data monitoring, fault warnings and maintenance reminders. The quotation should define the communication equipment, network requirements and enabled functions.
07 Request an LGGPM-175 Quotation
Request an LGGPM-175 quotation with your required pressure, average and peak air demand, operating hours, available power supply, quantity and destination.
Share the station manifold layout and the air-demand profile of the production areas that will be connected.
Leave A Message