The LGGPM-200 delivers two-stage PM VSD air supply in the 160 kW power class for central stations serving substantial factory demand. Air delivery is 33.6 m³/min at 0.8 MPa, with a DN80 outlet and a unit size of 2500 × 2126 × 2130 mm.
Its airflow, cabinet size and handling weight should be reviewed together when expanding a station. If it will operate alongside other compressors, provide the existing operating sequence and demand profile so that the proposed control arrangement can be assessed.
1. 160 kW capacity for central-station expansion
The LGGPM-200 delivers 33.6 m³/min at 0.8 MPa with a 160 kW motor. This duty point helps assess additional plant capacity against measured demand and existing station output.
2. Two-stage compression with shared pressure rise
The first and second compression stages divide the required pressure increase, with oil-mist cooling between them. This provides the core two-stage compression arrangement for the air-cooled package.
3. Direct PM drive for variable station demand
The drive combines a permanent magnet motor, inverter and direct transmission. Speed control responds to changing air consumption within the selected operating configuration.
4. Variable-speed axial fan cooling
The 160 kW air-cooled package uses variable-speed axial fan cooling. The axial fan arrangement supports cooling airflow through the package; plan adequate inlet air and a clear hot-air discharge route.
5. Defined dimensions for station expansion
The unit measures 2500 × 2126 × 2130 mm and weighs 3570 kg. These figures support delivery-route and room-layout checks; allow additional space for service and cooling airflow.
6. DN80 outlet with pressure-specific performance
The DN80 air outlet connects the compressor to the air system. Delivery is 34.5 m³/min at 0.7 MPa and 30.0 m³/min at 1.0 MPa, allowing selection at the pressure the process needs.
7. Local control and remote monitoring support
The touch-screen controller provides local operating information, while the series IoT system supports remote data checks and service reminders when configured and connected.
HUADA LGGPM-200 160 kW air-cooled two-stage PM VSD screw compressor, shown with an orange enclosure and dark panels.
| Parameter | LGGPM-200 |
|---|---|
| Model | LGGPM-200 |
| Compressor type | Two-stage permanent magnet VSD screw compressor |
| Motor power | 160 kW |
| Air delivery at 0.7 MPa | 34.5 m³/min |
| Air delivery at 0.8 MPa | 33.6 m³/min |
| Air delivery at 1.0 MPa | 30.0 m³/min |
| Air delivery at 1.2 MPa | 23.8 m³/min |
| Drive arrangement | Direct drive |
| Starting method | Variable-frequency starting |
| Motor speed | 1500 rpm |
| Cooling method | Air cooling; variable-speed axial fans |
| Discharge temperature | Ambient temperature ± 15°C |
| Power supply | 380 V / 3-phase / 50 Hz |
| Lubricating oil quantity | 90 L |
| Noise level | 82 ± 2 dB(A) |
| Dimensions (L × W × H) | 2500 × 2126 × 2130 mm |
| Unit weight | 3570 kg |
| Air outlet | DN80 |
Air-delivery values correspond to the individual pressure points shown; they are not a VSD minimum-to-maximum flow range. Confirm the required pressure configuration and site conditions when ordering. Motor speed is a specification reference, not a stated VSD speed range; compare noise levels under equivalent measurement conditions.
Pressure and demand: For a central station expansion or a multi-compressor plant system, provide average and peak consumption, working hours and pressure losses to the point of use. Use 33.6 m³/min for the 0.8 MPa duty point.
Electrical and cooling provision: Check the 160 kW motor and 380 V / 3-phase / 50 Hz supply with the installation team. The axial fan system requires an unobstructed cooling-air inlet and a suitable hot-air discharge route.
Handling and connections: Plan for the 2500 × 2126 × 2130 mm cabinet, 3570 kg unit weight and DN80 connection. Obtain the installation drawing and allow the required service and ventilation clearances.
Air quality and site conditions: Specify the receiver, dryer and filters for the required process air quality. Report high temperature, high humidity, severe cold, altitude or heavy dust so that the proposed configuration can be reviewed for the actual site.
| Before you order | What to confirm |
|---|---|
|
Quotation requirements |
Please provide your required operating pressure, average and peak air demand, power supply, order quantity and destination. |
|
Equipment scope |
The quotation specifies the selected compressor configuration and any receiver, dryer, filters or accessories included. |
|
Delivery and shipment |
Production lead time and shipping arrangements are quoted according to the selected configuration, quantity and destination. |
|
Technical documentation |
Please identify any documentation or destination-specific requirements needed for your purchasing process so that we can assess them for the selected configuration. |
|
Warranty and after-sales support |
Warranty coverage, service arrangements and spare-parts support are defined in the agreed quotation and order documents. |
Explore HUADA’s manufacturing facilities and request the technical documentation relevant to your selected configuration and destination.
View our factory
Review qualification documents
What airflow does the LGGPM-200 provide at different pressures?
Air delivery is 34.5 m³/min at 0.7 MPa, 33.6 m³/min at 0.8 MPa, 30.0 m³/min at 1.0 MPa and 23.8 m³/min at 1.2 MPa. Specify the pressure required by the application when selecting the configuration.
What cooling arrangement does this 160 kW model use?
The LGGPM-200 is air-cooled and uses variable-speed axial fans. A process cooling-water circuit is not required for this version; adequate cooling-air supply and hot-air discharge remain essential.
Can the LGGPM-200 operate in a station with other compressors?
A multi-compressor project should be reviewed as a complete system. Provide the existing machines, operating sequence, pressure settings and demand profile so that control compatibility and the proposed loading arrangement can be confirmed.
What oil quantity and outlet are specified?
The lubricating-oil quantity is 90 L and the air outlet is DN80. Confirm the supplied connection details and maintenance procedure when preparing the installation and service plan.
07 Request an LGGPM-200 Quotation
Request an LGGPM-200 quotation with your required pressure, average and peak air demand, operating hours, available power supply, quantity and destination.
For a station expansion, include the existing compressor sequence, pressure settings and treatment-system ratings.
Leave A Message