The HUADA SED-150+ is an air-cooled SED+ series screw air compressor delivering 23.5 m³/min at 0.8 MPa from a 110 kW motor. An IE5 permanent magnet motor, dual VFD control and a DN80 outlet provide a defined package for a high-volume industrial air station.
Item NO.:
SED-150+Product Origin:
Quanzhou, Fujian, ChinaColor:
Gray with orange trimProduct weight:
2262 kgShipping Port:
XiamenLead Time:
Depends on configuration
The SED-150+ is a 110 kW two-stage, oil-injected PM VSD compressor for plants moving to a higher-capacity supply through a DN80 connection. Air delivery is 23.5 m³/min at 0.8 MPa, with a DN80 outlet and a unit size of 2300 × 1500 × 1850 mm.
Its air-cooled arrangement and cabinet dimensions support planning for an equipment-room installation. Review the production demand, ventilation and dryer capacity together before finalizing the compressor configuration.
1. 110 kW capacity through a DN80 outlet
The SED-150+ delivers 23.5 m³/min at 0.8 MPa with a 110 kW motor. This operating point helps size a high-volume plant air supply and the receiver, dryer and filters connected to it.
2. Direct-drive IE5 permanent magnet motor
The 110 kW drive combines an IE5 permanent magnet motor, variable-frequency starting and direct transmission. Two-stage compression shares the pressure rise across the compression process.
3. Dual VFD control for main motor and cooling fan
The main motor and cooling-fan drive use current-vector variable-frequency control. Main-motor speed responds to air consumption to support regulation around the selected pressure setpoint.
4. Variable-speed axial fan cooling
A variable-speed axial fan arrangement provides air cooling for the 110 kW package. Coordinate the fresh-air supply and exhaust route with the equipment-room layout.
5. Split construction for maintenance access
The split construction is designed to support routine inspection and access to service components. The intake filter and automatic inlet valve should be included in the maintenance plan for the operating environment.
6. Defined handling load and service footprint
The unit measures 2300 × 1500 × 1850 mm, weighs 2262 kg and has a DN80 air outlet. Use these figures for delivery-route, pipework and room-layout planning, with additional service and ventilation clearance.
7. Monitoring support for plant maintenance
HUADA Smart Cloud supports remote data monitoring, fault warnings and maintenance reminders. Confirm the communication configuration and network requirements for the planned installation.
HUADA SED-150+ 110 kW air-cooled two-stage PM VSD screw air compressor, shown in gray with orange trim.
| Parameter | SED-150+ |
|---|---|
| Model | SED-150+ |
| Compressor type | Two-stage oil-injected PM VSD screw compressor |
| Motor power | 110 kW |
| Motor efficiency class | IE5 permanent magnet motor |
| Air delivery at 0.7 MPa | 24.5 m³/min |
| Air delivery at 0.8 MPa | 23.5 m³/min |
| Air delivery at 1.0 MPa | 19.7 m³/min |
| Air delivery at 1.2 MPa | 17.6 m³/min |
| Drive arrangement | Direct drive |
| Starting method | Variable-frequency starting |
| Motor speed | 1500 rpm |
| Cooling method | Air cooling; variable-speed axial fan arrangement |
| Discharge temperature | Ambient temperature ± 15°C |
| Power supply | 380 V / 3-phase / 50 Hz |
| Lubricating oil quantity | 60 L |
| Noise level | 82 ± 3 dB(A) |
| Dimensions (L × W × H) | 2300 × 1500 × 1850 mm |
| Unit weight | 2262 kg |
| Air outlet | DN80 |
| Product origin | Quanzhou, Fujian, China |
Air-delivery values correspond to the individual pressure points shown; they are not a VSD minimum-to-maximum flow range. Motor speed is a specification reference, not a stated speed range. Confirm the required pressure configuration and site conditions when ordering, and compare noise levels under equivalent measurement conditions.
Pressure and demand: For a high-volume industrial air station with DN80 distribution, provide average and peak air consumption, operating hours and pressure losses to the point of use. Use 23.5 m³/min for the 0.8 MPa duty point.
Electrical and cooling provision: The motor power is 110 kW and the power supply is 380 V / 3-phase / 50 Hz. Plan the electrical connection, cooling-air supply and exhaust routing before locating the compressor alongside the treatment equipment.
Handling and connections: Allow for the 2300 × 1500 × 1850 mm cabinet, 2262 kg unit weight and DN80 outlet. Obtain the installation drawing and add the required access, service and ventilation clearances.
Air quality and site conditions: Select the receiver, dryer and filters for the required moisture, particulate and oil limits. Report high temperature, high humidity, severe cold or heavy dust so that the proposed configuration can be reviewed for the actual environment.
| Before you order | What to confirm |
|---|---|
|
Quotation requirements |
Please provide your required operating pressure, average and peak air demand, power supply, order quantity and destination. |
|
Equipment scope |
The quotation specifies the selected compressor configuration and any receiver, dryer, filters or accessories included. |
|
Delivery and shipment |
Production lead time and shipping arrangements are quoted according to the selected configuration, quantity and destination. |
|
Technical documentation |
Please identify any documentation or destination-specific requirements needed for your purchasing process so that we can assess them for the selected configuration. |
|
Warranty and after-sales support |
Warranty coverage, service arrangements and spare-parts support are defined in the agreed quotation and order documents. |
Explore HUADA’s manufacturing facilities and request the technical documentation relevant to your selected configuration and destination.
View our factory
Review qualification documents
What airflow does the SED-150+ provide at different pressures?
Air delivery is 24.5 m³/min at 0.7 MPa, 23.5 m³/min at 0.8 MPa, 19.7 m³/min at 1.0 MPa and 17.6 m³/min at 1.2 MPa. Specify the required pressure configuration when requesting a quotation.
How is the cooling system controlled?
The SED-150+ is air-cooled and uses an axial cooling-fan arrangement with variable-frequency control. The main motor also has VSD control. Keep the cooling-air inlet and hot-air discharge path clear in the final installation.
What lubricating-oil quantity should be used for service planning?
The specified lubricating-oil quantity is 60 L. Follow the supplied filling and level-check procedures; the amount required during a particular service operation depends on the procedure and the oil remaining in the system.
Can the standard configuration be used in every environment?
High temperature, high humidity, severe cold and heavy dust require a configuration review. Provide the actual site conditions so that ventilation and any non-standard provisions can be assessed before ordering.
07 Request an SED-150+ Quotation
Request an SED-150+ quotation with your required pressure, average and peak air demand, operating hours, available power supply, quantity and destination.
Provide the DN80 connection layout, electrical supply, ventilation conditions and required process-air quality.
Leave A Message