The HUADA SED-100+ is an air-cooled SED+ series screw air compressor delivering 16.5 m³/min at 0.8 MPa from a 75 kW motor. The 75 kW package combines an IE5 permanent magnet motor, dual VFD control and a G2 outlet for a plant air network with variable consumption.
Item NO.:
SED-100+Product Origin:
Quanzhou, Fujian, ChinaColor:
Dark gray with orange trimProduct weight:
1810 kgShipping Port:
XiamenLead Time:
Depends on configuration
The SED-100+ supplies two-stage, oil-injected PM VSD compression for plants reviewing an air station in the 75 kW power class. Air delivery is 16.5 m³/min at 0.8 MPa, with a G2 outlet and a unit size of 2000 × 1470 × 1800 mm.
The cabinet size and G2 outlet should be reviewed together with the distribution network, electrical provision and treatment capacity. Match capacity at the required pressure rather than selecting by the model number alone.
1. 75 kW output for a plant air network
The SED-100+ delivers 16.5 m³/min at 0.8 MPa with a 75 kW motor. Use the selected pressure point to assess supply to several production areas and the associated treatment equipment.
2. IE5 motor efficiency with direct transmission
The 75 kW permanent magnet motor is rated IE5 and drives the two-stage compression assembly directly. The motor efficiency class identifies the motor; complete-system performance also depends on the operating duty.
3. Demand-responsive control of the main drive
Current-vector control varies main-motor speed to help maintain the pressure setpoint as consumption changes. A separate variable-frequency control function governs the cooling-fan drive.
4. Variable-speed axial fan cooling
The SED-100+ uses variable-speed axial fan cooling. Its air-cooled layout requires ventilation planning but no process cooling-water circuit for the compressor.
5. Planned access for filtration and maintenance
The inlet filter and integrated inlet valve form part of the air-management system. The split construction supports routine access to service components within the enclosure.
6. Cabinet and handling data for a station upgrade
The unit measures 2000 × 1470 × 1800 mm, weighs 1810 kg and has a G2 air outlet. Use these figures for delivery-route, pipework and room-layout planning, with additional service and ventilation clearance.
7. Connected operating-data visibility
HUADA Smart Cloud can provide remote operating information, abnormal-condition warnings and maintenance reminders when the required communication equipment and network access are in place.
HUADA SED-100+ 75 kW air-cooled two-stage PM VSD screw air compressor, shown in dark gray with orange trim.
| Parameter | SED-100+ |
|---|---|
| Model | SED-100+ |
| Compressor type | Two-stage oil-injected PM VSD screw compressor |
| Motor power | 75 kW |
| Motor efficiency class | IE5 permanent magnet motor |
| Air delivery at 0.7 MPa | 17.5 m³/min |
| Air delivery at 0.8 MPa | 16.5 m³/min |
| Air delivery at 1.0 MPa | 12.5 m³/min |
| Air delivery at 1.2 MPa | 11.2 m³/min |
| Drive arrangement | Direct drive |
| Starting method | Variable-frequency starting |
| Motor speed | 1500 rpm |
| Cooling method | Air cooling; variable-speed axial fan arrangement |
| Discharge temperature | Ambient temperature ± 15°C |
| Power supply | 380 V / 3-phase / 50 Hz |
| Lubricating oil quantity | 45 L |
| Noise level | 78 ± 3 dB(A) |
| Dimensions (L × W × H) | 2000 × 1470 × 1800 mm |
| Unit weight | 1810 kg |
| Air outlet | G2 |
| Product origin | Quanzhou, Fujian, China |
Air-delivery values correspond to the individual pressure points shown; they are not a VSD minimum-to-maximum flow range. Motor speed is a specification reference, not a stated speed range. Confirm the required pressure configuration and site conditions when ordering, and compare noise levels under equivalent measurement conditions.
Pressure and demand: For a plant air station serving multiple production areas, provide average and peak air consumption, operating hours and pressure losses to the point of use. Use 16.5 m³/min for the 0.8 MPa duty point.
Electrical and cooling provision: The motor power is 75 kW and the power supply is 380 V / 3-phase / 50 Hz. Assess the electrical supply and ventilation layout together with the capacity of the existing station equipment.
Handling and connections: Allow for the 2000 × 1470 × 1800 mm cabinet, 1810 kg unit weight and G2 outlet. Obtain the installation drawing and add the required access, service and ventilation clearances.
Air quality and site conditions: Select the receiver, dryer and filters for the required moisture, particulate and oil limits. Report high temperature, high humidity, severe cold or heavy dust so that the proposed configuration can be reviewed for the actual environment.
| Before you order | What to confirm |
|---|---|
|
Quotation requirements |
Please provide your required operating pressure, average and peak air demand, power supply, order quantity and destination. |
|
Equipment scope |
The quotation specifies the selected compressor configuration and any receiver, dryer, filters or accessories included. |
|
Delivery and shipment |
Production lead time and shipping arrangements are quoted according to the selected configuration, quantity and destination. |
|
Technical documentation |
Please identify any documentation or destination-specific requirements needed for your purchasing process so that we can assess them for the selected configuration. |
|
Warranty and after-sales support |
Warranty coverage, service arrangements and spare-parts support are defined in the agreed quotation and order documents. |
Explore HUADA’s manufacturing facilities and request the technical documentation relevant to your selected configuration and destination.
View our factory
Review qualification documents
What airflow does the SED-100+ provide at different pressures?
Air delivery is 17.5 m³/min at 0.7 MPa, 16.5 m³/min at 0.8 MPa, 12.5 m³/min at 1.0 MPa and 11.2 m³/min at 1.2 MPa. Specify the required pressure configuration when requesting a quotation.
Does the IE5 rating describe the whole compressor?
IE5 is the efficiency class of the permanent magnet motor. Evaluate the complete compressor at the required pressure and airflow, together with the plant load profile and downstream pressure losses.
How should I use the noise specification for room planning?
The SED-100+ noise specification is 78 ± 3 dB(A). Room surfaces, distance, ventilation openings and measurement conditions affect the level at a work area, so compare equipment under equivalent conditions.
What must be checked before connecting the G2 outlet?
Confirm the supplied connection details, pipe supports and isolation arrangement. Size the distribution line and treatment equipment for the selected pressure and airflow, including the expected pressure loss.
07 Request an SED-100+ Quotation
Request an SED-100+ quotation with your required pressure, average and peak air demand, operating hours, available power supply, quantity and destination.
Include the existing pipework connection, treatment-system ratings and any planned increase in plant air demand.
Leave A Message