The HUADA SED-75+ is an air-cooled SED+ series screw air compressor delivering 12.5 m³/min at 0.8 MPa from a 55 kW motor. Dual variable-frequency control and an IE5 permanent magnet motor help match the air supply to production shifts, while an air-cooled cabinet keeps installation independent of a process cooling-water circuit.
Item NO.:
SED-75+Product Origin:
Quanzhou, Fujian, ChinaColor:
Blue-gray with orange trimProduct weight:
1440 kgShipping Port:
XiamenLead Time:
Depends on configuration
The SED-75+ is a 55 kW two-stage, oil-injected PM VSD compressor for factories building a shared production-line air supply. Air delivery is 12.5 m³/min at 0.8 MPa, with a G2 outlet and a unit size of 1800 × 1250 × 1600 mm.
Its G2 outlet and pressure-specific output figures provide a basis for reviewing a production-line upgrade. Check both average consumption and short demand peaks, then coordinate compressor capacity with storage and downstream treatment.
1. 55 kW capacity for shared production lines
The SED-75+ delivers 12.5 m³/min at 0.8 MPa with a 55 kW motor. This duty point supports sizing a common air supply for machines operating together across a production shift.
2. IE5 PM drive for a production-line air supply
The 55 kW IE5 permanent magnet motor uses direct transmission to the two-stage compression assembly. Variable-frequency starting and speed control adapt the drive to the production load.
3. Current-vector control across production shifts
The main motor and cooling-fan drive both use variable-frequency control. Main-motor speed responds to air demand to help regulate the selected pressure as the number of active machines changes.
4. Variable-speed axial fan cooling
Variable-speed axial fan cooling removes heat from the air-cooled package. The 55 kW installation needs adequate fresh cooling air and a discharge route that limits hot-air recirculation.
5. Filtered intake and accessible service components
Intake filtration reduces the contaminants entering the compressor. The split construction supports access for routine inspections and maintenance, with service intervals set for the actual operating environment.
6. Installation data for a production-room upgrade
The unit measures 1800 × 1250 × 1600 mm, weighs 1440 kg and has a G2 air outlet. Use these figures for delivery-route, pipework and room-layout planning, with additional service and ventilation clearance.
7. Remote status checks across shifts
HUADA Smart Cloud supports operating-data monitoring, fault warnings and service reminders for maintenance personnel. Specify the communication hardware and enabled functions with the quotation.
HUADA SED-75+ 55 kW air-cooled two-stage PM VSD screw air compressor, shown in blue-gray with orange trim.
| Parameter | SED-75+ |
|---|---|
| Model | SED-75+ |
| Compressor type | Two-stage oil-injected PM VSD screw compressor |
| Motor power | 55 kW |
| Motor efficiency class | IE5 permanent magnet motor |
| Air delivery at 0.7 MPa | 12.8 m³/min |
| Air delivery at 0.8 MPa | 12.5 m³/min |
| Air delivery at 1.0 MPa | 9.6 m³/min |
| Air delivery at 1.2 MPa | 8.6 m³/min |
| Drive arrangement | Direct drive |
| Starting method | Variable-frequency starting |
| Motor speed | 1500 rpm |
| Cooling method | Air cooling; variable-speed axial fan arrangement |
| Discharge temperature | Ambient temperature ± 15°C |
| Power supply | 380 V / 3-phase / 50 Hz |
| Lubricating oil quantity | 40 L |
| Noise level | 78 ± 3 dB(A) |
| Dimensions (L × W × H) | 1800 × 1250 × 1600 mm |
| Unit weight | 1440 kg |
| Air outlet | G2 |
| Product origin | Quanzhou, Fujian, China |
Air-delivery values correspond to the individual pressure points shown; they are not a VSD minimum-to-maximum flow range. Motor speed is a specification reference, not a stated speed range. Confirm the required pressure configuration and site conditions when ordering, and compare noise levels under equivalent measurement conditions.
Pressure and demand: For a shared production-line network working across multiple shifts, provide average and peak air consumption, operating hours and pressure losses to the point of use. Use 12.5 m³/min for the 0.8 MPa duty point.
Electrical and cooling provision: The motor power is 55 kW and the power supply is 380 V / 3-phase / 50 Hz. Review power availability together with room ventilation and the hot-air exhaust route for the planned operating hours.
Handling and connections: Allow for the 1800 × 1250 × 1600 mm cabinet, 1440 kg unit weight and G2 outlet. Obtain the installation drawing and add the required access, service and ventilation clearances.
Air quality and site conditions: Select the receiver, dryer and filters for the required moisture, particulate and oil limits. Report high temperature, high humidity, severe cold or heavy dust so that the proposed configuration can be reviewed for the actual environment.
| Before you order | What to confirm |
|---|---|
|
Quotation requirements |
Please provide your required operating pressure, average and peak air demand, power supply, order quantity and destination. |
|
Equipment scope |
The quotation specifies the selected compressor configuration and any receiver, dryer, filters or accessories included. |
|
Delivery and shipment |
Production lead time and shipping arrangements are quoted according to the selected configuration, quantity and destination. |
|
Technical documentation |
Please identify any documentation or destination-specific requirements needed for your purchasing process so that we can assess them for the selected configuration. |
|
Warranty and after-sales support |
Warranty coverage, service arrangements and spare-parts support are defined in the agreed quotation and order documents. |
Explore HUADA’s manufacturing facilities and request the technical documentation relevant to your selected configuration and destination.
View our factory
Review qualification documents
What airflow does the SED-75+ provide at different pressures?
Air delivery is 12.8 m³/min at 0.7 MPa, 12.5 m³/min at 0.8 MPa, 9.6 m³/min at 1.0 MPa and 8.6 m³/min at 1.2 MPa. Specify the required pressure configuration when requesting a quotation.
How does the compressor respond when production demand changes?
Current-vector VSD control adjusts the permanent magnet motor speed in response to demand, while the cooling-fan drive also uses variable-frequency control. Select the operating configuration around the required pressure and the plant load profile.
Is 1500 rpm the full VSD speed range?
1500 rpm is the motor-speed specification. It is a single reference value, not a minimum-to-maximum VSD operating range. Request the operating limits for the selected machine configuration when these are needed for the project.
Does VSD guarantee the same energy saving at every site?
Savings depend on the demand profile, operating pressure, running hours and the compressor system being compared. Review measured air demand and the expected loading pattern when assessing operating cost.
07 Request an SED-75+ Quotation
Request an SED-75+ quotation with your required pressure, average and peak air demand, operating hours, available power supply, quantity and destination.
Share the production schedule, average and peak consumption, and the capacity of the existing receiver, dryer and filters.